// dallas_temp.ino - DS18B20 (1-Wire) digital temperature sensor driver
|
||
|
|
// -------------------------------------------------------------------------------------------------
|
||
|
|
// Uses the OneWire + DallasTemperature libraries (libraries/OneWire.zip, libraries/DallasTemperature.zip)
|
||
|
|
// to talk to one or two DS18B20 sensors sharing a SINGLE 1-Wire data bus on pin TEMP_DALLAS_PIN
|
||
|
|
// (a 4.7k pull-up resistor between DATA and VCC is required on the bus, as usual for 1-Wire).
|
||
|
|
// Enabled per-clock via USE_DALLAS_TEMP in clocks.h; the pin itself is set via TEMP_DALLAS_PIN.
|
||
|
|
// Used (as of this writing) by CLOCK_3, CLOCK_5, CLOCK_6A, CLOCK_7, CLOCK_12, CLOCK_14, CLOCK_15,
|
||
|
|
// CLOCK_15a, CLOCK_16, CLOCK_20, CLOCK_26, CLOCK_30, CLOCK_31, CLOCK_35, CLOCK_40..CLOCK_49 (Nixie/VFD
|
||
|
|
// UNFI board revisions), CLOCK_51, CLOCK_53..CLOCK_57A and CLOCK_71 - see clocks.h for the exact list.
|
||
|
|
//
|
||
|
|
// Because a DS18B20 conversion takes up to ~750ms, readings are NOT taken with a blocking call.
|
||
|
|
// Instead a request/poll pattern is used: requestDallasTemp() kicks off a conversion, and getTemp()
|
||
|
|
// is called repeatedly (every ~200ms from timeProgram() in the core .ino) until DS_delay has elapsed,
|
||
|
|
// at which point the converted value is actually fetched from the sensor. See the two functions below.
|
||
|
|
// =================================================================================================
|
||
|
|
#ifdef USE_DALLAS_TEMP //DS18B20 sensor
|
||
|
|
|
||
|
|
// Change HERE 0<>1, to swap sensors!!!
|
||
|
|
// NOTE: these two macros are not referenced anywhere else in this file (or the rest of the project) -
|
||
|
|
// looks like dead/leftover code; swapping sensor order today has to be done differently (see below).
|
||
|
|
#define SENSOR1 0
|
||
|
|
#define SENSOR2 1
|
||
|
|
#define TEMPERATURE_PRECISION 12 // DS18B20 resolution in bits (9-12); 12 bits = 0.0625C steps, ~750ms conversion time
|
||
|
|
|
||
|
|
#include <OneWire.h>
|
||
|
|
#include <DallasTemperature.h>
|
||
|
|
OneWire oneWire(TEMP_DALLAS_PIN); // Set up a OneWire instance to communicate with OneWire devices
|
||
|
|
DallasTemperature tempSensors(&oneWire); // Create an instance of the temperature sensor class
|
||
|
|
DeviceAddress thermometer1, thermometer2; // 64-bit ROM addresses of sensor #1 / #2, read once in setupDallasTemp()
|
||
|
|
boolean requested = false; // true while a conversion is in progress (request sent, result not yet fetched)
|
||
|
|
unsigned long lastRequest = millis(); // millis() timestamp of the last requestTemperatures() call
|
||
|
|
boolean DallasOK = true; //is any measure from Dallas thermometer?
|
||
|
|
float lastTemperature = 0; // NOTE: written nowhere, read nowhere else in the project - appears to be dead/unused
|
||
|
|
char lastTemperatureStr[5] = "----"; // NOTE: only ever written (see getTemp() below), never read back anywhere - looks unused/vestigial
|
||
|
|
unsigned long intervalTemp = 30000; // Do a temperature measurement every 30sec
|
||
|
|
unsigned long DS_delay = 800; // Reading the temperature from the DS18x20 can take up to 750ms
|
||
|
|
|
||
|
|
// Indexes into the shared temperature[]/humid[] arrays (declared in ESP32_UniClock2.ino) assigned to
|
||
|
|
// this driver's sensor(s) at setup time. Multiple sensor drivers (Dallas/DHT/I2C) share those arrays,
|
||
|
|
// each claiming the next free slot via the global useTemp counter - see setupDallasTemp() below.
|
||
|
|
byte d1Ptr = 0;
|
||
|
|
byte d2Ptr = 0;
|
||
|
|
|
||
|
|
void setupDallasTemp() {
|
||
|
|
regPin(TEMP_DALLAS_PIN,"TEMP_DALLAS_PIN");
|
||
|
|
pinMode(TEMP_DALLAS_PIN,OUTPUT);
|
||
|
|
#if defined(ESP8266)
|
||
|
|
oneWire.reset(); // ESP8266 needs an explicit bus reset before the first transaction; ESP32 does not
|
||
|
|
delay(200); //200ms
|
||
|
|
#endif
|
||
|
|
tempSensors.begin(); // Start the temperature sensor
|
||
|
|
tempSensors.setResolution(TEMPERATURE_PRECISION);
|
||
|
|
tempSensors.setWaitForConversion(false); // Don't block the program while the temperature sensor is reading
|
||
|
|
delay(100); //100ms
|
||
|
|
// Blocking probe done ONCE at boot: request a conversion and wait out the full 800ms here (setup()
|
||
|
|
// isn't time-critical), just so we can count/enumerate the sensors below. During normal operation
|
||
|
|
// (requestDallasTemp()/getTemp()) the same conversion is done non-blocking instead.
|
||
|
|
tempSensors.requestTemperatures();
|
||
|
|
delay(800);
|
||
|
|
int counter = 0;
|
||
|
|
while ((tempSensors.getDeviceCount() == 0) && (counter<5)) {
|
||
|
|
if (counter>3) {
|
||
|
|
DPRINT("No DS18x20 temperature sensor found on GPIO"); DPRINTLN(TEMP_DALLAS_PIN);
|
||
|
|
resetSensors();
|
||
|
|
}
|
||
|
|
counter++;
|
||
|
|
delay(100);
|
||
|
|
} //end while
|
||
|
|
|
||
|
|
// useDallasTemp: 0 = no sensor, 1 = single sensor, 2 = two sensors on the same bus.
|
||
|
|
// The two DS18B20s are NOT told apart by their ROM address/serial number - they are simply
|
||
|
|
// enumerated by their scan order on the bus (DallasTemperature index 0 and index 1, see
|
||
|
|
// getAddress()/getTempCByIndex() below), which is whatever order the library's internal 1-Wire
|
||
|
|
// search finds them in. There is no user-facing way here to pin a physical sensor to a fixed
|
||
|
|
// index; the SENSOR1/SENSOR2 macros above look like an abandoned attempt at that.
|
||
|
|
useDallasTemp = tempSensors.getDeviceCount();
|
||
|
|
if (useDallasTemp>0) {
|
||
|
|
d1Ptr = useTemp; //remember the pointers of sensors
|
||
|
|
useTemp++;
|
||
|
|
if (useDallasTemp>1) {
|
||
|
|
d2Ptr = useTemp;
|
||
|
|
useTemp++;
|
||
|
|
}
|
||
|
|
DPRINT("DS18B20 sensors found:"); DPRINTLN(useDallasTemp);
|
||
|
|
if (!tempSensors.getAddress(thermometer1, 0)) DPRINTLN("Unable to find address for Device 0");
|
||
|
|
if ((useDallasTemp>1) && !tempSensors.getAddress(thermometer2, 1)) DPRINTLN("Unable to find address for Device 1");
|
||
|
|
// Kick off one more conversion right away (rather than waiting for the normal once-a-minute
|
||
|
|
// trigger in requestDallasTemp()) so a real reading is available soon after boot.
|
||
|
|
// POSSIBLE BUG: this only delays 200ms, but getTemp() below requires DS_delay (800ms) to have
|
||
|
|
// elapsed since the request before it will actually fetch anything - with only 200ms elapsed,
|
||
|
|
// getTemp() just returns immediately here without reading temperature[]. `requested` stays true,
|
||
|
|
// so the real fetch only happens later, whenever timeProgram()'s periodic getTemp() call is
|
||
|
|
// reached ~800ms after this request - i.e. this call does not actually pre-populate temperature[]
|
||
|
|
// before setup() returns, despite appearances.
|
||
|
|
requestDallasTemp(true);
|
||
|
|
delay(200);
|
||
|
|
getTemp();
|
||
|
|
}
|
||
|
|
}
|
||
|
|
|
||
|
|
// Called every ~200ms from timeProgram() (with force=false). Does NOT block: requestTemperatures()
|
||
|
|
// with setWaitForConversion(false) (set in setupDallasTemp()) just tells the sensor(s) to start
|
||
|
|
// converting and returns immediately; the actual value is picked up later by getTemp() once enough
|
||
|
|
// time has passed. EEPROMsaving is checked because 1-Wire bus timing is sensitive to interrupts/delays,
|
||
|
|
// and EEPROMsaving also doubles as a "display refresh suspended" flag elsewhere in the project.
|
||
|
|
void requestDallasTemp(boolean force) {
|
||
|
|
if (EEPROMsaving) return;
|
||
|
|
|
||
|
|
// Old, no-longer-used scheme: re-request every intervalTemp (30s) regardless of clock time.
|
||
|
|
//if (force || (!requested && ((millis()-lastRequest) > intervalTemp))) { //request a new reading
|
||
|
|
// Current scheme: instead of a fixed interval, a new conversion is requested once per minute,
|
||
|
|
// exactly 1 second before prm.tempStart (the second-of-minute when the display starts showing the
|
||
|
|
// temperature) - so by the time the display wants to show it, the ~750-800ms conversion has had
|
||
|
|
// time to finish and getTemp() already has a fresh value ready.
|
||
|
|
if (force || (!requested && (second()==prm.tempStart-1))) { //request a new reading
|
||
|
|
tempSensors.requestTemperatures(); // Request the temperature from the sensor (it takes some time to read it)
|
||
|
|
requested = true;
|
||
|
|
lastRequest = millis();
|
||
|
|
DPRINTLN("Temperature requested");
|
||
|
|
}
|
||
|
|
}
|
||
|
|
|
||
|
|
// Called every ~200ms from timeProgram() (and once directly from setupDallasTemp()). This is the
|
||
|
|
// other half of the async request/read pattern: it does nothing until DS_delay has elapsed since the
|
||
|
|
// matching requestDallasTemp() call, at which point the conversion is guaranteed finished and the
|
||
|
|
// (already-converted) value can be read from the sensor over 1-Wire without blocking/waiting.
|
||
|
|
void getTemp() { //get the earlier requested temperature data
|
||
|
|
static int errors = 0;
|
||
|
|
float tmp_temp;
|
||
|
|
|
||
|
|
if (!requested) return; // no conversion pending - nothing to fetch yet
|
||
|
|
if ((millis()- lastRequest) < DS_delay) return; // 1000 ms after requesting the temperature
|
||
|
|
// ^ comment says 1000ms but DS_delay is actually 800ms (see top of file) - conversion itself needs
|
||
|
|
// up to ~750ms at 12-bit resolution, so 800ms leaves a small safety margin.
|
||
|
|
if (EEPROMsaving) return; // bus busy (flash write in progress) - try again on the next ~200ms tick
|
||
|
|
|
||
|
|
requested = false; // mark conversion consumed; a new request is needed before we read again
|
||
|
|
if (tempSensors.getDeviceCount() == 0) {
|
||
|
|
// Sensor(s) no longer answering on the bus (unplugged, wiring fault, bus glitch, etc.)
|
||
|
|
// POSSIBLE BUG: temperature[d2Ptr] is zeroed unconditionally here, even when useDallasTemp<=1
|
||
|
|
// (i.e. only one sensor was ever configured and d2Ptr was never assigned an index, so it is
|
||
|
|
// still 0 - its C++ default). If some other sensor driver's reading happens to live at slot 0
|
||
|
|
// and this Dallas sensor's own slot (d1Ptr) is not 0, this line would stomp on that other
|
||
|
|
// sensor's temperature[] entry instead of (or in addition to) this one. Contrast with the
|
||
|
|
// success path below, which correctly guards the second-sensor update with `if (useDallasTemp>1)`.
|
||
|
|
temperature[d1Ptr] = 0; temperature[d2Ptr] = 0;
|
||
|
|
DallasOK = false;
|
||
|
|
resetSensors();
|
||
|
|
DPRINTLN("Missing TEMP sensor!");
|
||
|
|
// NOTE: decrementing lastRequest here has no actual effect on when the retry happens, because
|
||
|
|
// the trigger condition in requestDallasTemp() is `second()==prm.tempStart-1`, a fixed point in
|
||
|
|
// the minute, not a millis()-based interval check anymore (that scheme is the commented-out
|
||
|
|
// line above). So despite the "retry ASAP!" comment, the next request still only fires at the
|
||
|
|
// next occurrence of second()==prm.tempStart-1 (i.e. up to ~60s later), same as `errors` below.
|
||
|
|
lastRequest -= intervalTemp; //retry ASAP!
|
||
|
|
}
|
||
|
|
else {
|
||
|
|
delay(10);
|
||
|
|
tmp_temp = tempSensors.getTempCByIndex(0); // Get the temperature from the sensor
|
||
|
|
// DallasTemperature reports -127C (DEVICE_DISCONNECTED_C) when a read fails - checked here
|
||
|
|
// via "> -127" rather than comparing to the library's named constant.
|
||
|
|
if (tmp_temp > -127) {
|
||
|
|
tmp_temp = round(tmp_temp * 10.0) / 10.0; // round temperature to 1 digits
|
||
|
|
DallasOK = true;
|
||
|
|
// POSSIBLE BUG: writes to temperature[0] literally instead of temperature[d1Ptr] (used
|
||
|
|
// everywhere else, e.g. the DPRINT right below and in the "sensor missing" branch above).
|
||
|
|
// This happens to be equivalent today because setupDallasTemp() is always called first in
|
||
|
|
// setup() (see ESP32_UniClock2.ino), so d1Ptr is always 0 - but it's fragile: if any other
|
||
|
|
// sensor driver (DHT/I2C) were ever initialized before this one, or a config combined Dallas
|
||
|
|
// with another sensor type such that useTemp>0 at the point setupDallasTemp() runs, this
|
||
|
|
// sensor's reading would land in the wrong slot in temperature[], while d1Ptr would still
|
||
|
|
// point at its correctly-reserved (but now unwritten) slot.
|
||
|
|
temperature[0] = tmp_temp;
|
||
|
|
DPRINT("Dallas#1 temp:"); DPRINTLN(temperature[d1Ptr]);
|
||
|
|
dtostrf(temperature[0], 4, 1, lastTemperatureStr); // formats temperature[0] into lastTemperatureStr, which (see top of file) is never read anywhere
|
||
|
|
errors = 0; // any successful read clears the consecutive-error counter
|
||
|
|
if (useDallasTemp>1) {
|
||
|
|
temperature[d2Ptr] = round(tempSensors.getTempCByIndex(1) * 10.0) / 10.0; // round temperature to 1 digits
|
||
|
|
DPRINT("Dallas#2 temp:"); DPRINTLN(temperature[d2Ptr]);
|
||
|
|
}
|
||
|
|
}
|
||
|
|
else {
|
||
|
|
// Sensor answered on the bus but returned a bad/disconnected reading (-127C) this cycle.
|
||
|
|
DPRINT("Temp sensor error!!!");
|
||
|
|
DPRINTLN(tmp_temp);
|
||
|
|
errors++;
|
||
|
|
lastRequest -= intervalTemp; //retry ASAP! (see NOTE above - has no effect on the actual retry timing)
|
||
|
|
resetSensors();
|
||
|
|
}
|
||
|
|
}
|
||
|
|
// After 20 consecutive failed reads (~20 minutes, since retries are gated to once/minute), give up
|
||
|
|
// on the sensor entirely so the UI/display stops trying to show a Dallas temperature.
|
||
|
|
if (errors>20)
|
||
|
|
useDallasTemp = 0; //forget BAD sensor!!!
|
||
|
|
}
|
||
|
|
|
||
|
|
// Attempts to recover a 1-Wire bus that has stopped responding (called from getTemp() whenever a
|
||
|
|
// sensor is missing or returns a bad reading). Blocking (delay(500) x2 = ~1s total), but it's only
|
||
|
|
// invoked on error paths, not on every normal read cycle, so it doesn't affect steady-state timing.
|
||
|
|
void resetSensors() {
|
||
|
|
if (EEPROMsaving) return;
|
||
|
|
DPRINTLN("Reset sensors...");
|
||
|
|
//#if defined(ESP8266)
|
||
|
|
oneWire.reset();
|
||
|
|
//#endif
|
||
|
|
delay(500); //200ms
|
||
|
|
|
||
|
|
tempSensors.begin(); //try to restart sensor
|
||
|
|
tempSensors.setWaitForConversion(false);
|
||
|
|
tempSensors.getDeviceCount();
|
||
|
|
delay(500); //200ms
|
||
|
|
}
|
||
|
|
//-----------------------------------------------------------------------------------------------------
|
||
|
|
#else
|
||
|
|
// USE_DALLAS_TEMP not defined for this CLOCK_NN config: compile out to no-op stubs so the rest of the
|
||
|
|
// codebase (setup()/timeProgram() in ESP32_UniClock2.ino) can call these unconditionally.
|
||
|
|
void setupDallasTemp() {}
|
||
|
|
void requestDallasTemp(boolean force) {}
|
||
|
|
void getTemp() {}
|
||
|
|
void resetSensors() {}
|
||
|
|
#endif
|